![](/images/new-backgrounds/1185794/185794223x1.webp)
Section 8: Adjustment Procedures
4Turn dial (5) on test module (3) to position number 0.
5Connect the positive (+) probe of the multimeter to connection port (6) on test module (3).
6Connect the negative
7Ensure the multimeter is for DC voltage reading.
8Place a label without the
9Adjust VR8 potentiometer (2) so that the multimeter value is less than 1.0 volts.
10Replace the label without the
11Observe the multimeter for a value of +3.0 volts more than the prior value read.
12Repeat steps 8 through 11 until the value is 3.0 volts.
13Test print labels to ensure proper function.
14Disconnect test module (3) from main circuit board (1).
15Disconnect test module (3) from main circuit board (1) and replace housing covers.
NOTE: Figure
OFFSET LABEL STOP POSITION ADJUSTMENT
The following procedure provides for fine adjustment of the label stop position for
NOTE: Figure
Location; and Figure
Schematics section provides additional guidance.
NOTE: Only the stop position is changed with the Offset potentiometer. The print position is changed using the Pitch potentiometer.
1 Turn the OFFSET (VR2) potentiometer dial midway of the scale.
NOTE: The Offset potentiometer is located on the upper surface of the left housing cover.
2Press and hold the FEED key while switching on the printer.
3Release the FEED key when the printer emits an audible beep.
|
|
|
|
| LCD DISPLAY: | TEST PRINT MODE |
|
|
| CONFIGURATION |
|
|
|
|
|
4 Press the ENTER key to advance to the next display.
SATO M10e Service Manual | PN: 9001113A | Page |