Section 8: Adjustment Procedures
NOTE: Refer to TP Test Module Usage in the TRoubleshooting section for additional instruction on test module usage.
4Turn dial (5) on test module (3) to position number 8.
5Connect the positive (+) probe of the multimeter to pin SIG (6) on test module (3).
6Connect the negative
7Ensure the multimeter is for DC voltage reading.
8Place a label without the
9Adjust VR7 potentiometer (2) so that the multimeter value is less than 1.0 volts.
10Replace the label without the
11Observe the multimeter for a value of +3.0 volts more than the prior value read.
12Repeat steps 8 through 11 until the value is 3.0 volts.
13Test print labels to ensure proper function.
14Disconnect test module (3) from main circuit board (1).
15Disconnect test module (3) from main circuit board (1) and replace housing covers.
NOTE: Figure
5
3
|
|
| 1A |
|
|
| 2A |
|
|
| 3A |
| 0 |
| 4A |
| 1 | 5A | |
8 |
| ||
|
| ||
|
| 6A | |
|
|
| |
7 |
| 2 | 1B |
|
|
| |
|
|
| 2B |
6 |
| 3 | 3B |
|
|
| |
5 | 4 |
| 4B |
|
| ||
| D SIG |
| 5B |
|
|
| |
GN |
| 6B | |
|
|
|
2 | 6 |
7 |
IEEE1284 +RSBOARD
4
1
3
|
| 1A |
|
| 2A |
|
| 3A |
0 |
| 4A |
1 | 5A | |
8 |
| 6A |
|
| |
7 | 2 | 1B |
|
| |
|
| 2B |
6 | 3 | 3B |
5 | 4 | 4B |
GND | SIG | 5B |
| 6B | |
|
|
Figure 8-10, Auto-Load Sensor Adjustment
SATO M10e Service Manual | PN: 9001113A | Page |