SATO 10e service manual Auto Load Sensor Adjustment, 9, Label Gap Sensor Adjustment

Models: 10e

1 126
Download 126 pages 27.74 Kb
Page 109
Image 109
Figure 8-9, Label Gap Sensor Adjustment

Section 8: Adjustment Procedures

 

 

0

1

 

8

 

 

 

 

7

 

 

2

 

 

 

5

6

3

 

 

 

5

4

 

 

D SIG

3

GN

 

 

2

7 6

1

1A 2A 3A 4A 5A 6A 1B 2B 3B 4B 5B 6B

84+ RS

BOARD

IEEE12

 

4

 

 

1A

 

 

2A

 

 

3A

0

 

4A

1

5A

8

 

 

6A

 

 

7

2

1B

 

 

 

 

2B

6

3

3B

5

4

4B

 

GND

SIG

5B

 

6B

3

 

 

 

Figure 8-9, Label Gap Sensor Adjustment

AUTO LOAD SENSOR ADJUSTMENT

This adjustment will require the use of a multimeter and the TP Test Module.

NOTE: Figure 10-4, Block Diagram, Figure 10-5, Accessories & Sensors Location; and Figure 10-6, Print Position Reference Diagram of the Diagrams & Schematics section provide additional instruction.

1 Remove the top, front, and left housing cover to access main circuit board (1, Figure 8-10).

NOTE: Figure 10-1 of the Diagrams & Schematics section provides guidance on housing cover removal.

2 Turn VR7 potentiometer (2) fully counter-clockwise.

AUTO LOAD SENSOR ADJUSTMENTManual background NOTE: An audible click should be heard.

3 Connect test module (3) to main circuit board connector (4).

SATO M10e Service Manual

PN 9001113A

Page 8-13