Installing Telephones and Adjuncts

Installing the Direct Station Selector

The DSS is an optional piece of telephone equipment. One or two DSSs can be connected to an MLX-28D or MLX-20L telephone.

NOTE:

Connect the DSS(s) before you install the MLX telephones.

Before installing the DSS, consider the following:

Auxiliary power is required under the following circumstances:

An MLX telephone with an MFM and two DSSs requires a 329A power unit.

An MLX telephone (without an MFM) has two DSSs requires a KS22911-L2 power unit.

An MLX telephone with one DSS and an MFM requires a KS22911-L2 power unit, 400B adapter, and the D6AP cord that is provided with the MFM.

If one carrier has three or more MLX telephones, each with a DSS attached, use aKS22911-L2 power unit, 400B adapter, and D6AP cord for each MLX telephone and DSS after the first two.

The total length of cords between the KS22911-L2 or 329A power supply and the MLX telephone can be no more than 50 ft (15 m).

Do not replace the 2-foot (61-cm) D8AC cord (packaged with the DSS) with a longer cord. Improper operation may result.

Connect each KS22911-L2 power supply to an AC outlet that is not controlled by a wall-switch.