Installing Telephones and Adjuncts

Tools

D-impact tool

788J1 impact tool

spudger

hand tools

SYSTIMAX Wiring Procedure

1.Locate the proper wall space. The cross-connect field will usually be to the right of the control unit. Leave enough space between the control unit and the cross-connect field to allow for system growth.

2.Attach the template to the wall or backboard with a staple gun, tacks, or tape. Make sure that the upper edge of the template outline is 70 inches (177 cm) above the floor and that the template is parallel to the floor.

3.Find the placement of the hardware on the template. See Figure 3-29.The first and third columns on the template show where the termination blocks go; the middle- column shows the place for the field-terminated blocks.

Keep the elements of a kit in the same-colored blocks. For example, the termination blocks of kit #1 go in the green section of column 1; the field-terminated block of kit #1 goes in the green section of column 2.

Connecting the Telephones to the Control Unit 3 - 55