Installing the PC, CAT, or Printer

Procedure: Connecting the Printer (50 Feet or More)

1.Plug the short end of the Z200A EMI cord into the SMDR jack on the control unit (the upper jack).

See Figure 5-4for the entire procedure.

2.Plug the other end of the Z200A EMI cord into a 355AF adapter.

3.Connect the female connector on the 355AF adapter to one end of the EIA crossover cable.

4.Connect the other end of the EIA cable to the 25-pin male connector of the Z3A2 ADU.

CAUTION:

If the printer is in a building outside the main building (control unit location), an ADU and an additional protector must be installed in each building. The ADUs and protectors provide both the control unit and the printer additional protection against lightning, inadvertent contact with power lines, and power currents induced by nearby power lines. See the installation notes packaged with the ADU for more information.

5.Plug one end of a D8W cord into the WALL jack on the Z3A2 ADU.

6.Plug the other end of this D8W cord into an ADU crossover cable.

7.Plug the other end of the ADU crossover cable into one of the jacks on a 400B2 power adapter.

8.Plug one end of a D6AP cord into the other jack of the 400B2 adapter.

5-18Connecting a Printer to the Control Unit

Page 237
Image 237