Installing the Control Unit

the carrier has a total of more than 45 MLX-20L telephones or 34- button analog multiline telephones installed

Unit Loads for Key or Behind Switch Mode

In a Key or Behind Switch system with four or fewer modules, no calculation is needed. The power supply (model 391A1) generally supports four modules of any type in Key or Behind Switch mode.

Auxiliary Power Units

The power supply provides 54 unit loads to each carrier. If the unit load requirement for a carrier exceeds 54, an auxiliary power unit is needed to allow that carrier to support an additional 27 unit loads.

CAUTION:

Running the system with more than 54 unit loads per carrier may not appear to do harm. However, this can cause the system to malfunction, thereby creating “no trouble found” situations, such as malfunctioning LEDs on multiline telephones, or power unit failure.

Any station connected to the modules in the last two slots receives power from the auxiliary power unit instead of from the power supply.

If an auxiliary power unit is required, complete instructions are provided later in this chapter, as the fourth step under “Installing the Processor.”

Unit Loads 2-19