AT&T Release 2.0 manual RJ11 and RJ14 Network Interface Hardware

Models: Release 2.0

1 381
Download 381 pages 43.04 Kb
Page 189
Image 189

Connecting the Control Unit to the Network Interface

RJ11 and RJ14 Network Interface Hardware

D 2 R c o r d s

CAUTION:

Incorrect wiring can damage the ports and cause them to stop functioning. Make sure you use the proper cords. For all GS/LS modules, do the following:

Use a D2R cable from an RJ11.

Do not use the Brand-Rex Quad cable from an E66 block.

If you cannot avoid using the Brand-Rex Quad cable, reverse the tip and ring leads at the E66 block to correct the mismatch.

RJ11 and RJ14 Network Interface Procedure

Follow this procedure to connect the RJ11 and RJ14 network interfaces to the control unit.

1. Test the central office trunks for proper connection (see “Testing Trunks” later in this chapter).

2 . Label the network interface jacks, the control unit module jacks, and the D2R cords properly (see “Labeling Trunks” later in this chapter).

3 . Plug one end of a D2R cord into the jack at the network interface and the other end into the appropriate trunk jack on the control unit.

4 . Dress the wires properly.

4-12Wiring

Page 189
Image 189
AT&T Release 2.0 manual RJ11 and RJ14 Network Interface Hardware, RJ11 and RJ14 Network Interface Procedure