Connecting the Control Unit to the Network Interface

Office Repeater Switch Settings

Table 4-22 and Table 4-23 show the power mode and artificial line-option settings for the office repeater. See Figure 4-11for the location of the option- setting screws.

Table 4-22. Office Repeater Power Mode Option Settings

 

 

Screw

 

 

S4

S5

 

 

Power Mode

Options

S2

S3

 

 

 

 

 

 

 

 

 

 

Line power

C, E, K

n/a

n/a

AB

B

 

 

 

 

 

 

 

 

 

 

-48 V with

 

 

 

 

 

 

 

sealing current

C, E, K

Y

OU

AA

B

 

 

 

 

 

 

 

 

 

 

-48 V without

 

 

 

 

 

 

 

sealing current

C, G, J

Y

OUT

AA

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Letters indicate those screws that are closed.

Table 4-23. Office Repeater Artificial Line Options

Line Loss

 

S1

 

S5

0 dB

 

C

n/a

7.5 dB

 

A

 

A

 

15 dB

 

B

 

B

 

 

 

 

 

 

Step 2: Mounting the CSU

After the options have been set on the signal monitor unit and the office repeater, mount the CSU shelf assembly into a relay rack, a cabinet, or as a standalone unit.

4-36Installing the Channel Service Unit

Page 213