Connecting the Control Unit to the Network Interface

Table 4-18. CSU Front Panel LEDs

L E D

LOCAL POWER

Network Side:

FAR END LOOPED

CRITICAL PWR

PULSES

FRAME LOSS

CRC ERROR

BPV

NEAR END LOOPED ALARM

System Side:

LOOPED

FRAME LOSS

LOW DENS

A C O

 

C o l o r

 

 

When Lit Indicates

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yellow

 

 

 

 

 

 

 

 

 

 

Local 117 VAC or -48 VDC is ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R e d

 

 

 

 

 

 

 

 

 

Far-end CSU looped if initiated by near-end

 

 

 

 

 

 

 

CSU.

 

Yellow

 

Power is on to critical circuits

 

Green

 

Normal incoming signal from network

 

Red

 

Loss of signal, loss of frame synch,

 

 

 

 

 

 

 

improper frame sequence, or unframed

 

 

 

 

 

 

 

signal

 

Red

 

CRC error detected

 

Red

 

Non-B8ZS violation detected when optioned

 

 

 

 

 

 

 

for B8ZS; other bipolar violations detected

 

Yellow

 

Loopback is activated

 

R e d

 

BER threshold exceeded (associated

 

 

 

 

 

 

 

contacts for an audible alarm are also

 

 

 

 

 

 

activated)

 

 

 

 

 

 

 

 

 

Yellow

 

 

 

 

 

Loopback activated on system side

 

Red

Loss of signal, loss of frame synch,

 

 

 

 

 

 

improper frame sequence, or unframed

 

 

 

 

 

 

signal

Red

Avg. ones density below threshold or

 

 

 

 

 

 

consecutive zeroes threshold

 

 

 

 

 

Yellow

 

 

Lights when ACO button is pressed when

 

 

 

 

 

 

ALARM LED is lit

Installing the Channel Service Unit 4-31

Page 208
Image 208