Connecting the Control Unit to the Network Interface
Table 4-18. CSU Front Panel LEDs
LEDColor
LOCAL POWER
Yellow
Network Side:
FAR END LOOPED Red
CRITICAL PWR Yellow
PULSESGreen
FRAME LOSS Red
CRC ERROR Red
BPVRed
NEAR END LOOPED Yellow
ALARM Red
System Side:
LOOPED Yellow
FRAME LOSS
Red
LOW DENS
Red
ACOYellow
When Lit Indicates
Local 117 VAC or -48 VDC is ON
Far-end CSU looped if initiated by near-end
CSU.
Power is on to critical circuits
Normal incoming signal from network
Loss of signal, loss of frame synch,
improper frame sequence, or unframed
signal
CRC error detected
Non-B8ZS violation detected when optioned
for B8ZS; other bipolar violations detected
Loopback is activated
BER threshold exceeded (associated
contacts for an audible alarm are also
activated)
Loopback activated on system side
Loss of signal, loss of frame synch,
improper frame sequence, or unframed
signal
Avg. ones density below threshold or
consecutive zeroes threshold
Lights when ACO button is pressed when
ALARM LED is lit
Installing the Channel Service Unit 4-31