Initializing and Testing the System

Testing Outgoing Automatic-Start Tie Trunks

Perform this test for automatic-start tie trunks that are two-way or outgoing only. If you are testing two-way automatic-start tie trunks, perform the incoming test as well.

1 . At any telephone that has access to an automatic-start tie trunk, press the first tie-trunk button.

The red LED next to the tie-trunk button just pressed turns on.

2.Pick up the handset.

NOTE:

In Hybrid/PBX systems with pooled tie trunks, press SA and dial the pool dial-out code.

The green LED next to the selected button turns on, and you hear ringing.

3.When the person answers, verify that you have good two-way communication and hang up.

The green LED should turn off, the red LED will turn off, and another red LED may turn on.

4.Repeat this procedure for each outgoing and two-way automatic-start tie trunk.

Testing Two-Way Dial-Repeating Tie Trunks

For two-way dial-repeating tie trunks, perform both of the dial-repeating tie trunk tests (incoming and outgoing).

Testing the System 7-19

Page 296