Connecting the Control Unit to the Network Interface

Table 4-2. Central Office Network Interface Codes

 

Trunk

Federal Interface

Network Interface

 

 

Type

 

Code for Trunk

 

 

 

 

 

 

 

 

 

 

 

 

 

LS central office trunk

 

02LS2

RJ11C, RJ14C

 

 

 

 

 

 

 

RJ21

 

 

 

 

 

 

 

 

 

GS central office trunk

 

02GS2

RJ11C, RJ14C,

 

 

 

 

 

 

 

RJ21

 

 

 

 

 

 

 

DID

 

02RV2-T

RJ11C, RJ14C,

 

 

 

 

 

 

 

RJ21

 

 

 

 

 

 

 

O P S

 

0L13C

 

RJ11C

 

Tie trunk

 

TL31M

R J 2 G X

 

 

 

 

 

 

 

DS1

 

04DU9-B

RJ48C/X

 

 

 

 

04DU9-C

See note below.

 

 

 

 

 

 

 

 

 

NOTE:

The preferred network interface is the RJ48X. With the RJ48X interface, if no connection is provided by the customer’s equipment, the T1 trunk’s receive pair is looped back to the transmit pair. This simplifies troubleshooting the T1 trunk.

In most installations, the network interface is connected through a cross- connect field to the control unit. However, for systems with fewer than 24 stations, the trunk wires can be directly connected to the control unit.

When constructing wiring fields between the network interface and the control unit, you must order hardware as individual parts. Do not use Interconnect Wiring or SYSTIMAX kits.

4-4Wiring