Connecting Data Equipment

NOTE:

The configuration shown in Figure 6-5is for asynchronous digital data transmission. For information on setting up synchronous digital data stations, see “Video Conferencing Data Stations” later in this chapter.

The maximum cord length from the data module to the telephone is 80 ft (24 m).

1.Connect the data terminal to the data module:

a.Connect an EIA-232-D cable to the SERIAL connector on the data terminal.

NOTE:

For any data terminal that has both COMl and COM2 connectors, make sure you use the one designated for data transmission. See the customer’s system administrator if you are not sure.

b.Make sure that the data module option settings for parity and speed are compatible with those settings of the data terminal. (Speed is synchronized automatically when the factory default settings remain unchanged.)

If you are not sure about the data terminal option settings, see the customer’s system administrator or the documentation packaged with the data module and data terminal.

c.Connect the other end to PORT 1 on the data module.

2.Plug the WP90110-L7 power supply cord into the connector labeled POWER on the data module.

6-14Data Stations