AT&T Release 2.0 manual Inserting the Signal Monitor Unit

Models: Release 2.0

1 381
Download 381 pages 43.04 Kb
Page 215
Image 215

Connecting the Control Unit to the Network Interface

c.Connect the DC Ioopback pair (if provided by the local telephone company) to terminals 11 and 12.

d.If the CSU is to be locally powered, connect the power supply leads to terminals 14 and 15.

Step 4: Inserting the Signal Monitor Unit

After setting the option switches, plug the signal monitor unit into the right side of the 551 T1 CSU.

The signal monitor unit has six LEDs and six bantam jacks (see Figure 4-10).

Table 4-24and Table 4-25show the functions of the LEDs and the test jacks on the front panel.

21-PIN I/O CONNECTOR

OPTIONS

SWITCH (DIP)

LEDs

Signal Monitor Unit

EQ

EQ

SM SM

SM SM

IN

OUT

MON IN

OUT MON

Figure 4-10. Signal Monitor Unit

4-38Installing the Channel Service Unit

Page 215
Image 215
AT&T Release 2.0 manual Inserting the Signal Monitor Unit