Connect External Alarms and Auxiliary Connections

Figure 46: 1151B2 Power Supply — Front

pwr_sup1 CJL 051496

Connect External Alarms and Auxiliary Connections

Note:

The AUX connector is part of the Processor Interface cable assembly (J1).

Alarm Input

Alarms can be generated on adjunct equipment, sent to the DEFINITY System, and recorded and reported as “external alarms.” A typical major alarminput is from a UPS.

1.Connect 1 major alarm input wire pair and 1 minor alarm input wire pair to the auxiliary field from the AUX connector (J1 on Processor Interface Cable). See Table 19.

Table 19: Alarm Inputs at AUX Connector

Alarm Input

Color

AUX Connector

Type

 

 

 

 

 

Major

White-Blue

AP1 (Pin 26)

 

Blue-White

Ground (Pin 1)

 

 

 

Minor

White-Orange

AP2 (Pin 27)

 

Orange-White

Ground (Pin 2)

 

 

 