Completing Installation and Cable Pinouts

TN760E Tie Trunk Option Settings

The TN760E Tie Trunk circuit pack interfaces between 4 tie trunks and the TDM bus. Two tip and ring pairs form a 4-wire analog transmission line. An E and M pair are DC signaling leads used for call setup. The E-lead receives signals from the tie trunk and the M-lead transmits signals to the tie trunk.

To choose the preferred signaling format (Table 31 and Table 32), set the switches on the TN760E and administer the port using Figure 69: TN760E Tie Trunk Circuit Pack (Component Side) on page 159 and Table 33: TN760E Option Switch Settings and Administration on page 159.

Table 31: Signaling Formats for TN760E

Mode

Type

 

 

E & M

Type I Standard (unprotected)

 

 

E & M

Type I Compatible (unprotected)

 

 

Protecte

Type I Compatible, Type I

d

Standard

 

 

Simplex

Type V

 

 

E & M

Type V

 

 

E & M

Type V Revised

 

 

Table 32: Signaling Type Summary

Signaling Type

Transmit (M-Lead)

Receive (E-Lead)

 

 

 

 

 

 

 

 

 

 

 

On-Hook

Off-Hook

On-Hook

Off-Hook

 

 

 

 

 

Type I Standard

ground

battery

open1/battery

ground

Type I Compatible

open1/battery

ground

ground

open1/

 

 

 

 

battery

 

 

 

 

 

Type V

open1/battery

ground

open

ground

Type V Reversed

ground

open

ground

open

 

 

 

 

 

1. An open circuit is preferred instead of battery voltage.