Installing and Cabling the Cabinets

2.If necessary, enter change terminal-parameters 603/302B1 to change the default system-level parameters and audio levels for these terminals.

Note:

For information about changing the default parameters and audio levels, refer to DEFINITY Application Notes available through the ITAC (International Technical Assistance Center).

3.Administer other forms listed under “Attendant Console” inAdministrator’s Guide for Avaya Communication Manager.

To administer an Avaya SoftConsole, see Administrator’s Guide for Avaya Communication Manager.

Save Translations

To save translations:

1.Enter save translation and press Enter. This copies the current system translations onto the translation card and takes about 10 minutes.

2.Remove the original translation card and replace with the backup card.

3.Repeat Step 1 for the backup translation card.

4.Remove the backup card and replace with the original translation card.

5.Label the backup card with the date and time of the backup and store in a secure place.

Add Translations

Refer to Administrator’s Guide for Avaya Communication Manager to add new terminals.

Install and Wire Telephones and Trunks

Note:

Only 1 pair of wires is available for emergency transfer, and 1 pair of wires is available for attendant console power.

This section provides wiring examples of installation procedures. These are examples only and actual wiring procedures may vary at each site.

The system can connect to all DTE terminals. The system can have RS-232 (or EIA-232) or DCP interfaces.

All wiring pinouts for port circuit packs are in the tables at the end of this chapter.