Avaya CMC1 manual Tac, Trunk Parameters, Trunk Group Administrable Timers

Models: CMC1

1 370
Download 370 pages 26.18 Kb
Page 119
Image 119

CAMA/E911 Installation

Figure 47: CAMA Trunk Group form (page 1)

 

 

 

 

 

Page 1 of 11

 

 

TRUNK GROUP

 

 

 

 

Group Number: 1

 

Group Type: cama

CDR Reports: y

Group Name: cama Trunk Group -

E911 COR:

1

TN: 1

TAC:

701

Direction: outgoing

Outgoing Display?

y CESID I Digits Sent:

0

 

Busy

Threshold:

99

 

 

 

TRUNK PARAMETERS

Trunk Type: wink-start

Outgoing Dial Type: r1mf

Trunk Termination: rc

2.On the Trunk Group screen (page 1), in the Group Type: field, enter cama.

3.In the Group Name: field, enter the desired name.

4.In the TAC: field, enter the desired trunk access code.

5.In the Outgoing Display: field, enter y.

6.In the CESID I Digits Sent: field, enter the number directed by the Central Office (CO) or the Public Safety Answering Point (PSAP).

7.Scroll to page 3 of the form.

Figure 48: Administrable Timers form (page 3)

Page 3 of 11

TRUNK GROUP

ADMINISTRABLE TIMERS

Outgoing Disconnect (msec): 400

Cama Outgoing Dial Guard (msec): 75

Outgoing Glare Guard (msec): 1000

Cama Wink Start Time (msec): 5000

Outgoing End of Dial (sec): 1 Outgoing Seizure Response (sec): 4 Disconnect Signal Error (sec): 30

8.On the Administrable Timers screen (page 3), you may need to adjust these fields according to your CO. Scroll to page 5.

Issue 10 June 2005 119