Adding or Removing Hardware

Administer the Bus Bridge

1.Type change system-parameters maintenance and press Enter.

2.On Page 2, Type y in the PKTINT 2 field.

3.Choose the port bandwidths or use the default and submit the form.

4.Verify the bus bridge LED is lit on the TN799DP C-LAN circuit pack. This indicates that the packet bus is enabled.

Test the Packet Bus and C-LAN Circuit Pack

Type test packet port-network 1 long and press Enter. For more

detail about these tests, refer to the test pkt command section in the Maintenance for Avaya DEFINITY Server CSI.

Resolve Alarms

Examine the alarm log. Resolve any alarms using Maintenance for Avaya DEFINITY Server CSI.

Enable Alarm Origination to INADS

1.Ask the regional Customer Software Administration to complete the Verify Customer Options steps. See Where to get additional help on page 22 for telephone numbers.

Note:

As part of the system registration process, the INADS Database Administrator enables Alarm Origination and customer options.

Verify Customer Options

To verify customer options:

1.Type display system-parameterscustomer-optionsand press Enter. Ensure that the G3 version field is V11.

2.If the customer was using Supplementary Services Protocol b or d on an ISDN-PRI trunk group before the upgrade, go to the QSIG Optional Features screen and ensure that the

Basic Call Setup field is y.

270 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways

Page 270