Avaya CMC1 manual Add Packet Bus Support, Disable Alarm Origination, Install Circuit Packs

Models: CMC1

1 370
Download 370 pages 26.18 Kb
Page 269
Image 269

Add Packet Bus Support

Add Packet Bus Support

Disable Alarm Origination

To disable alarm origination:

1.Type change system-parameters maintenance and press Enter.

2.Set the Alarm Origination Activated field to n.

! CAUTION:

If you do not disable Alarm Origination, the system may generate alarms, resulting in unnecessary trouble tickets.

3.For some DEFINITY ECS software versions, disable Cleared Alarm Notification and Restart Notification before submitting the form.

Save Translations

Type save translation and press Enter. This instructs the system to take all translation information in memory and write it to the translation card.

Install Circuit Packs

Install the appropriate TN circuit packs. See Table 56.

Table 56: Circuit Pack Locations for Packet Bus in PPN

Circuit Pack

Carrier

Quantity

Slot

 

 

 

 

TN799DP

Any

1

Any Available Port Slot

 

 

 

 

Issue 10 June 2005 269

Page 269
Image 269
Avaya CMC1 manual Add Packet Bus Support, Disable Alarm Origination, Install Circuit Packs