Installing and Cabling the Cabinets

Connect the 1152A1 PDU

! CAUTION:

The 1152A1 PDU has no ON/OFF switch. To connect or disconnect power to the 1152A1 PDU, simply insert or remove the power cable from the AC power receptacle on the rear of the 1152A1 PDU.

To connect the 1152A1 PDU:

1.Plug a power cord into the power socket on the rear of the 1152A1 Power Distribution Unit.

2.Plug the other end of the power cord into the power receptacle.

The 1152A1 PDU powers up, and the internal fans begin operating.

The 1152A1 PDU then runs through its Power On Self Test (POST), which takes less than 10 seconds. During the test, all the ports on the unit are disabled and the LEDs light up. For more information on the test, refer to the user’s guide that comes with the unit.

Connect the Cables

All of the ports on the front of the 1152A1 PDU are configured as data route-through ports for all data wires (pins 1, 2, 3 and 6).

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

 

Data &

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1152A1 Power

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Distribution Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC

Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Console

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48Vdc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use a standard CAT5, CAT6 or CAT6e straight-through Ethernet cable (not supplied), including all 8 wires (4 pairs) as shown in Connecting cables to telephones and other end devices on page 109.

Figure 43: Connecting telephones and other end devices to the 1152A1 PDU

Ethernet

Switch/Hub

1152A1 Power Distribution Unit

RJ-45 IN

RJ-45 OUT

End Device

 

1

 

2

45-RJ

3

4

 

 

5

 

6

 

7

 

8

data

data

data

spare

spare

data

spare

spare

1

2

3

4

5

6

7

8

Data In

Data & Power Out

1

2

3

4

5

6

7

8

data

data

data

DC +

DC +

data

DC -

DC -

1

 

2

 

3

45-RJ

4

 

5

 

6

 

7

 

8

 

108 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways

Page 108
Image 108
Avaya CMC1 manual Connect the 1152A1 PDU, Connect the Cables