Avaya CMC1 Install Off-Premises Station Wiring, Install Off-Premises or Out-of-Building Stations

Models: CMC1

1 370
Download 370 pages 26.18 Kb
Page 133
Image 133

Install Off-Premises Station Wiring

Install Off-Premises Station Wiring

The cabling for off-premises stations is provided by the local telephone company. These stations can appear on any of the RJ21X network interfaces provided for the CO trunks.

! CAUTION:

Use only an FCC-approved (or equivalent) analog type telephone (such as a 2500-type) as an off-premises station. The TN746B and TN2183 Analog Line circuit packs can be connected to off-premises stations.

To wire off-premises stations:

1.Install an A25D cable between the RJ21X network interface and a sneak fuse panel.

2.At the MDF, connect jumper wires between 1 row/connecting block in the green field and up to 3 rows/connecting blocks in the purple field to concentrate the analog line pairs.

3.Connect an A25D cable between the sneak fuse panel and the terminal block connector associated with the green row in Step 2.

4.Install a green label on the terminal block to identify the remote location.

5.Administer per Administrator’s Guide for Avaya Communication Manager.

Install Off-Premises or Out-of-Building Stations

Out-of-building campus stations are those telephones not physically located in the same building as the equipment room but are located on the same property.

Analog Off-Premises Stations

Figure 62: Connections for 1 to 8 Out-of-Building Analog Telephones on page 134 shows the connections for 1 to 8 off-premises analog telephones. Only analog telephones connected to TN746B, TN2183, or TN769 Analog Line circuit packs can be installed out-of-building.

The maximum distance from the system cabinet to the out-of-building voice terminal is 6000 feet (1828.8 m) using 24 AWG (#5) (0.26 mm2) wire.

Issue 10 June 2005 133

Page 133
Image 133