Install Emergency Transfer Unit and Associated Telephones

Figure 64: 808A Emergency Transfer Panel

EMERGENCY

TRANSFER

PANEL

 

POWER

 

 

 

 

TRUNK/TEST SWITCHES

 

CIRCUIT

 

 

 

1

 

 

TRUNK OPTION

2

1

 

1

LOOP

GROUND

3

 

 

2

START

START

4

2

 

 

5

 

 

 

 

6

3

BOTH SWITCHES MUST BE

 

7

 

 

4

THROWN TO ACTIVATE

 

8

TRUNK OPTION

 

9

 

 

 

 

10

5

 

 

 

12

TRANSFER TEST SWITCH

 

 

 

 

ACTIVATED

NORMAL

 

 

 

 

OPERATION

 

 

 

 

 

 

TRUNK IDENTIFICATION

 

TRUNK

EXT

LOC

 

LINE

 

 

 

 

 

 

 

 

808A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

led808a LJK 040896

Figure notes:

 

 

 

 

 

1.

808A emergency transfer panel

3.

Trunk identification label

2.

Circuit start selection switches

4.

25-pair male connector

 

 

 

 

 

 

 

 

 

 

3.Locate the circuit start selection switches. See Figure 64: 808A Emergency Transfer Panel on page 139. These are the first 10 two-position switches on the left side of the 808A. The switches set each of the 5 incoming trunk lines to either loop start or ground start. Two switches are used for each of the 5 circuits; switches 1 and 2 are used for circuit 1, switches 3 and 4 are used for circuit 2, and so forth. See Table 25.

For loop start, set the switches to the left. For ground start, set the switches to the right.

Issue 10 June 2005 139

Page 139