Install Emergency Transfer Unit and Associated Telephones

4.Connect the ST leads on the yellow emergency transfer row/connecting block for each emergency transfer telephone to the ST terminal appearance in the yellow trunk/auxiliary field. The ST terminal leads should be terminated on the following pairs: 1, 4, 7, 10, 13, 16, 19, or 22 (the first pair of any 3-pair group).

5.Connect the ST leads from the terminal in Step 4 to the assigned terminal in the blue or white station distribution field.

Trunk/Auxiliary Field: Telephone Used for Emergency Transfer and as Normal Extension

To connect the telephone to the trunk/auxiliary field:

1.Connect a pair of wires between the -48V and GRD terminals on the yellow emergency transfer row/connecting block to the EM TRANS RELAY PWR terminal. See

Figure 66: Connections for Telephone Used for Emergency Transfer and as Normal Extension on page 144.

2.Connect CO trunk leads from the purple field to the TC terminals on the yellow emergency transfer row/connecting block for each trunk.

3.Connect CO trunk leads from the green field to the TK terminals on the yellow emergency transfer row/connecting block for each trunk.

4.Connect telephone leads from the purple analog line board row/ connecting block to the LC terminals on the yellow emergency transfer row/connecting block for each telephone.

5.Connect ST leads on the yellow emergency transfer row/connecting block for each emergency transfer telephone to the ST terminal appearance in the purple trunk/auxiliary field.

6.Connect the ST leads from the terminal in Step 5 to the assigned terminal in the blue or white station distribution field.

Telephone Installation

To connect the telephone to the MDF:

1.Connect the telephone to the information outlet.

2.Install patch cords/jumper wires between the system side and the station side of the station distribution field on the MDF.

Issue 10 June 2005 145

Page 145
Image 145