Install and Wire Telephones and Trunks

To wire an analog tie trunk:

1.Before installing the Tie Trunk circuit pack, set the option switches as described in Chapter 2: Completing Installation and Cable Pinouts.

2.Install cross-connect jumpers to connect the pins from the Tie Trunk circuit pack to the appropriate leads on the external tie trunk. Names of the tie trunk leads must be determined from the manufacturer or supplier of the external trunk circuit. The example in Figure 34 shows a DEFINITY System tie trunk connected to a DEFINITY System tie trunk.

3.Administer on the Trunk Group Screen. See Administrator’s Guide for Avaya Communication Manager.

Digital Tie Trunk Example

Figure 35: Digital Tie Trunk Wiring

Figure notes:

 

 

1.

External trunk

4.

LO (Balanced output pair)

2.

DS1 interface circuit pack, position 1C06

5.

LI

3.

LO

6.

LI (Balanced input pair)

 

 

 

 

To wire a digital tie trunk:

1.Before installing the DS1 Interface circuit pack, set the option switches according to Chapter 2: Completing Installation and Cable Pinouts.

2.Install cross-connect jumpers to connect the pins from the digital trunk circuit pack to appropriate pins on the external digital trunk.

3.Administer the DS1 Interface circuit pack on the DS1 and Trunk Group Screens. See Administrator’s Guide for Avaya Communication Manager.

Issue 10 June 2005 89

Page 89
Image 89
Avaya CMC1 manual Digital Tie Trunk Example, Digital Tie Trunk Wiring