Adding or Removing Hardware

PRI-to-BRI converter

Figure 110 shows typical connections from the PRI-to-BRI converter to the coaxial facility. The Communication Manager administration PC is connected to the RS-232 connector on the front of the PRI converter circuit pack.

Figure 110: Typical PRI to BRI converter cabling

8

7

(2B+D)

(2B+D)

1

(2B+D)

Figure notes:

1.TN464GP DS1 circuit pack and PR-to-BRI converter circuit pack

2.Communication Manager administration PC

3.RS-232 cable to front of converter circuit pack

4.888B 75-ohm coaxial converter

5.Coaxial connection to 2-Mbps facility

0022_1 PDH 062596

6.Coaxial cable from PRI converter circuit pack to coaxial converter

7.TN464GP circuit pack

8.PRI-to-BRI converter circuit pack

9.Jumper coaxial cable

10.Inset showing connections on rear of carrier

Note:

The inset shows details of the cable connections between the circuit packs.