Adding or Removing Hardware

Figure 97: Typical nonsignaling wideband configuration

4

1

3

 

 

2

POWER

AUX PORT COM PORT

MODEM

NETWORK

 

 

 

DTE

6

5

1

3

7

6

 

 

 

 

 

2

 

 

9

8

cydf049 RPY 123097

Figure notes:

1.

Wideband endpoint (wire per manufacturer)

6.

DS1/E1 circuit pack

2.

Modular cord

7.

Main distribution frame (MDF)

3.

103A or modular wall jack

8.

Distance limit depends on cable and

4.

Channel service unit (CSU)

 

endpoint type.

5.

H600-307 cable to DTE connector on CSU

9.

A25D 25-pair cable (male-to-male)

 

 

 

 

If using a CSU, the distance between connections may be up to 1300 ft. (397.2 m). The maximum distance to the endpoint depends on the type of cable and the specifications of the endpoint.

Signaling configuration

A signaling connection from the system to a wideband endpoint passes through a bandwidth controller. The distance between the system and the bandwidth controller depends on the type of cable and controller. Figure 98 shows connections with and without a CSU.

316 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways

Page 316
Image 316