Avaya CMC1 manual Type display communication-links and press Return

Models: CMC1

1 370
Download 370 pages 26.18 Kb
Page 225
Image 225

Task table

3.Type list configuration software-versionand press RETURN. The Software Versions screen appears.

4.In the UPDATE FILE section, check the Update State field for a software patch:

If there is a patch number, then a patch has been applied.

If the field is none in memory, there is no software patch in system memory.

Note:

If you need to restore the system to the old version, you must also download a patch onto the system.

5.In the SOFTWARE VERSION section note the current version listed in the Memory Resident field.

Check link status

To check link status:

1.Type display communication-links and press RETURN.

Ensure that the link administration is the same as before the upgrade.

2.Type status link number and press RETURN for each administered link. Check these fields for the corresponding values:

Link Status = connected

Service State = in service

If any of the links are not up, take the necessary corrective action to restore the link

3.Type list signaling-group press RETURN.

Check the system to ensure that the signaling group administration is the same as before the upgrade.

4.For each signaling group, type status signal number and press RETURN. Ensure that the Group State field is in-service.

If the system had ISDN-PRI D-channel links administered, check that those links are in-service.

5.Execute the following commands to ensure that the administration is the same as before the upgrade:

list station

list trunk-group

list hunt-group

list data-module

Issue 10 June 2005 225

Page 225
Image 225
Avaya CMC1 manual Type display communication-links and press Return, Type list signaling-group press Return