Set Up System Access

4. Set the operating mode as described in the following table.

Type of

How to set the operating mode

Data

 

Module

 

 

 

8400B+

Type AT&F and press Enter. Type ATS24=1 and

 

press Enter. Type AT&WØ and press Enter to

 

save the operating mode into non-volatile RAM.

 

 

7400A

Type AT&F and press Enter. Type AT&WØ and

7400B+

press Enter to save the operating mode into

 

non-volatile RAM.

 

 

5.Disconnect the terminal from the data module and reconnect the data module to the system cabling.

Setting the 7400B+ options

To set the options on a 7400B+ data module:

1.Set the DIP switches for the 7400B+ using Table 7. The DIP switches are located inside the unit. To access them

a.Remove the power cord from the unit.

b.Remove the cover from the top rear of the unit.

c.Set the dip switches.

d.Replace the cover.

e.Connect the power cord.The unit performs a self test.

2.If any switches were set in step 1, cycle the power to the data module so that the firmware can read the new switch settings.

Table 7: DIP Switch Settings (7400B+)

Option

DIP Switch

Setting

 

 

 

No Telephone Connected

1

On

 

 

 

Data Metering

5

Off

 

 

 

Suppress Touch-tone/Dial Tone

6

Off

 

 

 

Speakerphone Disable/Enable

7

Off

 

 

 

Busyout on Local Loop

8

Off

 

 

 

Unused DIP Switches

2, 3, and 4

Off

 

 

 