Install multimedia call handling (MMCH)

Connect the endpoints

Use the following procedure and Figure 100 to connect the endpoints:

Figure 100: Typical multimedia call handling connections

Figure notes:

 

 

1.

DCP telephone, 2 or 4 wire to

7.

25-pair cable to digital line circuit pack

 

match type of circuit pack

8.

25-pair cable to BRI circuit pack or NT1,

2.

Personal computer

 

4-to-2 wire adapter

3.

BRI adapter

9.

Avaya Media Server

4.

D8W cord

10.

Multimedia-interface circuit pack

5.

103A or modular wall jack

11.

Voice conditioner circuit pack

6.Main distribution frame

1.Each PC MMCH endpoint must contain a BRI adapter.

2.Connect a DCP telephone to a digital line circuit pack. The DCP telephone must be used in conjunction with the PC. Refer to the tables at the end of this chapter for the pinout of the digital line circuit pack.

3.Connect the PC BRI adapter to any BRI port on the Avaya Media Server. Refer to the tables at the end of this chapter for the pinout of an ISDN BRI circuit pack.

Administer the system

1.Call INADS and notify the representative that the Multimedia Call Handling (MMCH)? field on page 2 of the customer-options form must be changed to y.

2.Logoff the terminal and then log back on the terminal to see your changes.

Issue 10 June 2005 319

Page 319
Image 319