Completing Installation and Cable Pinouts

Enable Alarm Origination to INADS

No External Modem Installed (or No Alarm Origination to INADS)

To enable alarms when no external modem is present:

1.Type change system-parameters maintenance and press Enter.

2.Type n in the Alarm Origination Activated to OSS Numbers field and press

Enter.

3.For some DEFINITY ECS software releases, enable Cleared Alarm Notification and Restart Notification before the submitting the form.

External Modem Installed

To enable alarms when an external modem is present:

1.Type change system-parameters maintenance and press Enter.

2.Type y in the Alarm Origination Activated to OSS Numbers field and press

Enter.

3.For some DEFINITY ECS software releases, enable Cleared Alarm Notification and Restart Notification before the submitting the form.

4.Be sure the system is part of the INADS database by calling the INADS Database Administrator at the Technical Service Center (TSC). Verify that INADS can dial into the system and that the system can dial out to INADS.

As part of the system registration process, the INADS Database Administrator enables Alarm Origination and customer options.

Note:

When calling from a remote modem, you may need to disable error correction to allow the modems to connect successfully. For example, the AT&T Paradyne KeepInTouch® modem may require the “AT\n0” command.

Register the Switch for Maintenance

The Automatic Registration Tool (ART) is a web-based tool that permits Avaya field technicians and Remote Technical Services (RTS) Database Administration (DBA) to register Avaya direct channel products.

The product that you are registering must have switch connectivity through:

the INADS line

an IP address