Avaya CMC1 manual Wiring block must be locally engineered

Models: CMC1

1 370
Download 370 pages 26.18 Kb
Page 349
Image 349

Install music-on-hold

4.Install patch cord/jumper wires at the MDF to connect tip and ring to the information outlet at the music source.

5.Set the Protection/Paging switch to C1.

6.Connect a modular cord from the information outlet to the music source.

7.Connect -48V to pin 5 and -48V RET to pin 2 of J3 on the 909A/B. The power source may be an 1151A, 1151A2, or other approved power supply.

8.Administer the switch for the new equipment.

Figure 115: Typical nonregistered equipment connections (auxiliary access) for an MCC1, SCC1, or CMC1Media Gateway

 

J1

J2

4

5

4

 

5

 

 

J3

 

5

 

2

 

 

Figure notes:

 

 

1.

Customer-supplied music source

5.

Power supply for universal

2.

A25D 25-pair cable to auxiliary trunk

 

coupler

 

circuit pack

6.

103A or modular wall jack

3.

909A/B universal coupler

7.

4-pair modular cord

4.

Part of main distribution frame

8.

Tip and ring wires

 

 

 

 

Note:

A wiring block must be locally engineered.

Issue 10 June 2005 349