Avaya CMC1 TN464HP and TN2464CP Option Settings, Option Switch Settings on TN464HP and TN464CP

Models: CMC1

1 370
Download 370 pages 26.18 Kb
Page 160
Image 160

Completing Installation and Cable Pinouts

TN464HP and TN2464CP Option Settings

The TN464HP DS1/E1 Interface - T1/E1 circuit pack interfaces between a 24- or 32-channel Central Office/ISDN or tie trunk and the TDM bus.

Note:

The P designation means the circuit pack’s firmware is programmable. Refer to Upgrade Firmware on Programmable Circuit Packs on page 231 for more information.

Set the switches on the circuit pack to select bit rate and impedance match. See Table 34 and Figure 70: TN464HP and TN2464CP Option Settings on page 161. If the top switch setting is set to 32 channel, then set the lower switch setting to either 120 ohms or 75 ohms.

Table 34: Option Switch Settings on TN464HP and TN464CP

120 ohms

Twisted pair

 

 

75 ohms

Coaxial requiring 888B adapter

 

 

32 Channel1

2.048 Mbps

24 Channel1

1.544 Mbps

1.If the 24/32 channel switch is not set per administration (or vice versa), the circuit pack alarms and will not be present in the list configuration command.

160 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways

Page 160
Image 160
Avaya CMC1 manual TN464HP and TN2464CP Option Settings, Option Switch Settings on TN464HP and TN464CP