Installing and Cabling the Cabinets

Analog Station or 2-Wire Digital Station Example

This example is typical of the 2-wire digital stations,2-wire analog stations, analog CO trunks, DID trunks, and external alarms. See Figure 33.

Figure 33: 2500-Type Analog Telephone Wiring

T 2 28 T3

R 3 03 R3

2500wire RBP 040596

Figure notes:

1. 2500-type analog station

2. 2-wire analog line circuit pack

 

 

To wire analog telephone equipment:

1.Choose a peripheral to connect (such as a 2-wire digital station).

2.Choose the port circuit pack to use and its carrier and slot number. For example, TN2183 Analog Line, Cabinet 1, Carrier C, Slot 1.

3.Choose a port circuit on the port circuit pack, for example port 3.

4.Install cross-connect jumpers to connect the pins from the 2-wire station to the appropriate pins on the port circuit pack.

5.Administer using Administrator’s Guide for Avaya Communication Manager.

Analog Tie Trunk Example

Figure 34: Analog Tie Trunk Wiring

T1

26

29

T2

R1

1

4

R2

T11

27

 

30

T12

 

 

R11

2

5

R12

E1

28

31

E2

M1

3

6

M2

 

tie_wire RBP 040596

Figure notes:

 

1. External trunk or adapter

2. Tie trunk circuit pack

 

 