Avaya CMC1 manual Restoring DS1 administration, Releasing the DS1 circuit pack

Models: CMC1

1 370
Download 370 pages 26.18 Kb
Page 331
Image 331

Install DS1/T1 CPE loopback jack

Restoring DS1 administration

1.At the management terminal, open the DS1 administration form. Enter change ds1 UUCSS, where UU is the cabinet number, C is the carrier letter, and SS is the slot number of the DS1 board.

2.Change to page 2 of the DS1 administration form.

3.Change the value of the TX LBO field to the original value that you wrote down when you were Administering the DS1 for the test on page 327.

4.Press ENTER to make the changes, CANCEL to quit without changes.

Releasing the DS1 circuit pack

1.Release the DS1 circuit pack. From the management terminal, enter release board UUCSS, where UU is the cabinet number, C is the carrier letter, and SS is the slot number of the DS1 board.

2.Leave the loopback jack in place.

Testing the DS1 span from the smart jack to the network interface termination or fiber multiplexer (MUX)

1.Have the service provider run a smart-jack loopback test against the network interface wiring that links the smart jack to the CO (section 3 in Figure 102 through Figure 104).

2.If the tests fails, there is a problem on the network side. Have the service provider correct it.

Testing the DS1 span from the loopback jack to the smart jack

Test the short length of customer premises wiring between the loopback jack and the smart jack (Section 2 in the following 3 figures) using a loopback that overlaps this section of the span.

Have the DS1 service provider at the CO end run a local ICSU line loopback test.

Have the DS1 service provider at the CO end run a local DS1 payload loopback test.

Run a far-end ICSU line loopback, using the procedure below.

Note:

This test cannot isolate the problem if there are problems in the wiring between the far-end CO and the far-end ICSU. You must coordinate this test with the DS1 service provider.

1.From the management terminal, enter test ds1-loopUUCSS far-csu-loopback-test-begin, where UU is the cabinet number, C is the carrier letter, and SS is the slot number of the DS1 board.

Issue 10 June 2005 331

Page 331
Image 331
Avaya CMC1 manual Restoring DS1 administration, Releasing the DS1 circuit pack