Adding or Removing Hardware

Install malicious call trace

The malicious call trace (MCT) voice recorder connects directly to the tip and ring connections of a TN763/D auxiliary trunk circuit pack. See Figure 113. The 909A/B universal coupler provides seizure control to the recorder.

Figure 113: Malicious call trace

J1

7

J2 6

73

82

J3

5

2

 

 

 

cydf038 PDH 091696

Figure notes:

 

 

1.

Malicious call trace voice recorder

4.

Power supply for universal coupler

2.

25-pair cable (T, R, S, S1, Sz, SZ1) to

5.

To SZ1 on TN763/D connector

 

TN763/D auxiliary trunk circuit pack

6.

Tip and ring wires

3.

909A/B universal coupler

7.

CBS1/C1 and CBS2/C2

 

 

 

 

Note:

A wiring block must be locally engineered.

Note:

909A couplers ships with one DW4B-DE cable and two DW8B-SE cables. The 909B ships with one KS-22911L2 power supply, one DW4B-DE cable, and two DW8B-SE cables.

1.Determine the port assignment of the recorder from the malicious call tracing form.

2.Install the 909A/B universal coupler on a vertical surface.

3.Connect the SZ, SZ1, S, and S1 leads from the 909A/B to an auxiliary trunk circuit pack.

a.Tip and ring connect from the voice recorder to the auxiliary trunk circuit pack (J1 on the 909A/B).

b.CBS1/C1 and CBS2/C2 connect from the voice recorder to J2 on the 909A/B.

346 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways