D. Add the two measurements taken and divide by two to give an average rolling radius value. Round this value to the nearest tenth (0.1).

EXAMPLE

Axle #1 87 cm (34.25)

Axle #2 86 cm (33.75)

Total

173 cm (68.00) 2 = 86 cm

 

(34.00)

Rounded Totals 86 cm (34.0)

E.To place the value into the monitor, use the digit select switch to select the necessary numbers. The monitor will accept values between 50.8 cm and 127.0 cm (20.0and 50.0).

F.Push the acknowledge/reset button again to enter the value into the monitor’s memory. The display will now go to “Programming Units of Ground Speed Measurement.” If no further calibration is needed, turn the ignition to the “OFF” position. If further calibration is needed in other areas, select the area to be calibrated with the rotary select switch and proceed as detailed for that switch position.