SECTION 2 - OPERATION

6.Service Interval Two Alarm Reset

NOTE: If any changes are made to the alarm, the accrued hours that have been recorded for service interval two will be reset to zero automatically during the alarm reset procedures. It is recommended that the alarm setting be changed once the service interval two setting has been reached and needs to be reset.

A.If you want to change the hour interval at which the audible alarm indicates that service interval two is required, follow the steps detailed in “Service Interval Two Reset” and push the acknowledge/reset button again.

B.The upper portion of the monitor will flash “ALR” and “SET” along with displaying the words “SET UP.” The lower portion of the monitor will show the current hour level setting at which the alarm will sound with the last digit flashing. Use the digit select switch to program the value between 10 and 1500 hours at which the alarm will notify the user to perform service interval two.

C.Push the acknowledge/reset button again to enter the value into the monitor’s memory. The display will now return to “Service Interval Two Reset” mode.

All possible programming for the service interval two position is now complete. If no further calibration is needed, turn the ignition to the “OFF” position. If further calibration is needed in other areas, select the area to be calibrated with the rotary select switch and proceed as detailed for that switch position.

Figure 2-100

2-68

Page 126
Image 126
Buhler 2425, 2335, 2290, 2375, 2360 manual Service Interval Two Alarm Reset