SECTION 5 - SPECIFICATIONS

ENGINE AIR INTAKE AND EXHAUST

 

2290

2335

 

2375

 

2360

2425

 

 

 

 

 

 

 

 

AIR INTAKE

 

 

 

 

 

 

 

Precleaning

 

Exhaust Aspirated w/ Precleaner

 

 

 

 

 

 

 

 

Air Filter Configuration

 

 

 

Primary (Outer)

 

 

 

 

 

Secondary (Inner)

 

 

 

 

 

 

 

 

 

Air Flow - L/S (CFM) @ 2100 RPM

382 (810)

413 (875)

 

414 (878)

 

507 (1075)

519 (1100)

 

 

 

 

 

 

 

 

EXHAUST OUTLET

 

 

 

 

 

 

 

MufflerType

Perforated tube and center plug with venturi for intake. Precleaner aspiration.

 

 

 

 

 

 

 

Air Flow - L/S (CFM) @ 2100 RPM

798 (1690)

873 (1850)

 

414 (878)

 

1132 (2400)

1261 (2675)

 

 

 

 

 

 

 

 

FUEL SYSTEM

 

 

 

 

 

 

 

 

2290

 

2335

2375

2360

 

2425

 

 

 

 

 

 

 

 

Fuel Tanks:

 

 

 

 

 

 

 

Total Capacity - L (gal.)

 

 

 

927 (245)

 

 

 

 

 

 

 

 

 

 

 

Usable Capacity - L (gal.)

 

 

 

871 (230)

 

 

 

 

 

 

 

 

 

 

 

Vented

 

 

 

Both Tanks

 

 

 

 

 

 

 

 

 

 

 

Fuel Filter

 

 

 

Single Element

 

 

 

 

 

 

 

Cold Start

 

Measured 4.8 cc shot of fluid at each switch activation.

 

 

 

 

Thermoguard protected above 27°C (81°F)

 

 

 

Fuel Flow

Drawn from left tank, passes through the engine fuel system. Return fuel goes

 

through the fuel cooler back to the right tank. Crossover pipe between the two

 

 

tanks. Separate fill spout and drain on each tank.

 

 

 

 

 

 

 

 

 

COOLING SYSTEM

 

 

 

 

 

 

 

 

2290

 

2335

 

2375

2360

2425

 

 

 

 

 

 

 

 

Coolant capacity - L (gal.)

 

59 (15.6)

 

 

60 (15.9)

60 (15.9)

 

 

 

 

 

 

 

Radiator Core Size (LxW) - mm (in.)

 

 

 

978 x 894 (38.5 x 35.2)

 

 

 

 

 

 

 

 

Fins per Inch

 

 

 

9

 

 

 

 

 

 

 

 

Number of Rows

6

 

6

 

7

6

7

 

 

 

 

 

 

 

 

Fan Diameter - mm (in.) x Blade

 

813 (32)

 

838 (33)

813 (32)

838 (33)

Pitch Width - mm (in.)

 

x 89 (3.5)

 

x 89 (3.5)

x 89 (3.5)

x 89 (3.5)

 

 

 

 

 

 

 

 

Number of Blades

 

 

 

8

 

 

 

 

 

 

 

 

 

Pressure Cap Setting - kPa (PSI)

 

 

 

97 (14)

 

 

 

 

 

 

 

 

 

 

Thermostat Opens

 

 

 

 

82°C (180°F)

 

 

 

 

 

 

 

 

 

 

Thermostat Full Open

 

 

 

 

93°C (200°F)

 

 

 

 

Type of System

Pressurized recirculating full flow bypass with filter and corrosion inhibitor.

 

 

 

 

 

 

 

 