SECTION 2 - OPERATION

If engine oil pressure continues to drop and reaches 100 kPa (15 psi), the EICS will react as detailed in “Low Engine Oil Pressure (below 100 kPa (15 psi)) at Any Engine Speed” in this manual.

The Operator cannot cancel or interrupt the derate sequence from occurring on the engine. The module does not recognize activation of, nor is it tied into the EICS acknowledge/reset button on the dash of the tractor.

If the tractor is shut down and then restarted, and the alarm condition still exists, (low engine oil pressure at engine speeds above 1200 rpm) the module will repeat the derate sequence. If the tractor is restarted and the alarm condition has been corrected, the tractor will return to normal operation. If the tractor is not shut down, and the alarm condition is corrected, the tractor will return to normal operation without having to shut it off and restart it.

2-78

Page 136
Image 136
Buhler 2425, 2335, 2290, 2375, 2360 manual Operation