SECTION 3 - LUBRICATION AND MAINTENANCE

EVERY 50 HOURS

OPERATION 21

Check the Engine Air Cleaner Connections

The air induction system pipe work must be checked for proper sealing.

On the 2360 and 2425 (N14), check to be sure that the hose clamps, attaching the pipe work between the turbocharger and air cleaner are tight and that no air can enter the air induction system without first passing through the air cleaner. (N14 engine shown in illustration)

On the 2290, 2335 and 2375 (QSM11), check the hose clamps, on the pipe work between the air cleaner and turbocharger. Make sure the clamps are tight and no air can enter the engine air induction system without first passing through the air cleaner.

1

Figure 3-36

3-28