SECTION 3 - LUBRICATION AND MAINTENANCE

EVERY 500 HOURS

If the batteries require removal, disconnect the cables as previously detailed. Loosen the wing nuts, 1, and lower the clamps, 2, downward. Lift the battery to be removed from the battery tray.

1

2

Figure 3-57

OPERATION 37

Check the Battery Electrolyte Level

To check the battery electrolyte level, clean the top of the batteries with a damp cloth.

Remove the six fill plugs, 1, from each battery. Check that the electrolyte level is 6 mm (1/4) below the filler neck of each cell. Add distilled or demineralized water as required. Do not overfill. Replace all fill plugs.

Check for loose cable connections. Tighten as required.

WARNING: BATTERIES CONTAIN SULFURIC ACID. IN CASE OF CONTACT WITH SKIN, FLUSH THE AFFECTED AREA WITH WATER FOR FIVE MINUTES. SEEK MEDICAL ATTENTION IMMEDIATELY.

WARNING: AVOID CONTACT WITH THE SKIN, EYES OR CLOTHING. WEAR EYE PROTECTION WHEN WORKING NEAR BATTERIES.

1

Figure 3-58

3-43

Page 268
Image 268
Buhler 2375, 2335, 2425, 2290, 2360 manual Check the Battery Electrolyte Level