SECTION 2 - OPERATION

4.Service Interval One Alarm Reset

NOTE: If any changes are made to the alarm, the accrued hours that have been recorded for service interval one will be reset to zero automatically during the alarm reset procedures. It is recommended that the alarm setting be changed once the service interval one setting has been reached and needs to be reset.

A.If you want to change the hour interval at which the audible alarm indicates service interval one is required, follow the steps detailed in “Service Interval One Reset” and push the acknowledge/reset button again.

B.The upper portion of the monitor will flash “ALR” and “SET” while displaying “SET UP.” The lower portion of the monitor will show the current hour level setting at which the alarm will sound with the last digit flashing. Use the digit select switch to program the value between 10 and 1500 hours at which the alarm will notify the operator to perform service interval one.

C.Push the acknowledge/reset button again to enter the value into the monitor’s memory. The display will now return to “Service Interval One Reset” mode.

All possible programming for the service interval one position is now complete. If no further calibration is needed, turn the ignition to the “OFF” position. If further calibration is needed in other areas, select the area to be calibrated with the rotary select switch and proceed as detailed for that switch position.

Figure 2-97

2-66

Page 124
Image 124
Buhler 2360, 2335, 2425, 2290, 2375 manual Service Interval One Alarm Reset