SECTION 4 - TROUBLESHOOTING

TRACTOR PERFORMANCE MONITOR

PROBLEM

POSSIBLE CAUSE

CORRECTION

 

 

 

 

 

 

Display blank

Loss of +12 VDC power

Replace fuse for TPM (3-amp

 

 

instrumentation fuse).

 

 

 

“Err” displayed

Recent loss of +12 VDC power

Reprogram the time of day

 

 

function.

 

Selected function is detected to

Reprogram the indicated function.

 

contain an invalid number

 

 

 

 

No AREA accumulation or

Incorrect installation of implement

Turn tractor ignition switch to ON,

AREA/HR prediction

status switch

performance monitor should

 

 

power-up. Press RESET (AREA)

 

 

switch, with AREA displayed; if

 

 

UP message was displayed, it

 

 

should clear. The UP message

 

 

should alternate on and off each

 

 

time the switch is pressed. If so,

 

 

check installation of the

 

 

implement status switch. Be sure

 

 

the trip spring to implement status

 

 

switch is correctly stretched. If no

 

 

implement status switch is being

 

 

used, be sure the “UP” indicator

 

 

does not show on the display.

 

Implement status switch input

Visually inspect the implement

 

inhibited due to broken or

status switch cable for damage. If

 

damaged cable or because

damage is found, replace the

 

implement status switch is

cable.

 

defective

 

 

 

 

No wheel slip indication

No axle speed input

Use the electronic instrument

 

 

cluster to check out the operation

 

 

of the transmission output speed

 

 

sensor. If the dash will not

 

 

indicate a ground speed, contact

 

 

your Buhler Versatile dealer.

 

No radar speed input

Use the distance measuring

 

 

feature of the performance

 

 

monitor to determine if the radar

 

 

is functioning. If not, contact your

 

 

Buhler Versatile dealer.

 

 

 

4-13