SECTION 3 - LUBRICATION AND MAINTENANCE

EVERY 1500 HOURS OR YEARLY

Check the front mounts, 1, for wear or deterioration and torque the mount bolts and nuts to 280 Nm (205 ft. lbs.). Torque the mounting bracket to engine bolts, 2, to 45 Nm (35 ft. lbs.).

OPERATION 57

Check the Engine Turbocharger

Connections

On the Model 2290, 2335 and 2375 (QSM11), check the exhaust pipe to turbo outlet clamp, 1. Torque the clamp to 9 Nm (80 in. lbs.). Torque the lower oil drain line cap screws, 2, to 27 Nm (239 in. lbs.). Tighten the upper oil supply line fitting, 3. 20 N m (177 in. lbs.)

Tighten the four nuts that mount the turbocharger to the exhaust manifold of the engine to 61 Nm (45 ft. lbs.).

2

1

 

 

Figure 3-96

1

3

 

 

2

 

Figure 3-97