4035197 Rev C D9865 Satellite Receiver Installation and Operation Guide 7-17
Ethernet MAC
Failure
Set MAC configuration
failed
Cause: Possible hardware
issue.
Remedy: Clear warnings,
reset the unit, and notify
customer service if problem
persists.
Errors like Fatal Bus
Error.
Clear Failure cleared
Ethernet PHY
Failure
Set Marvel switch
configuration failed
Cause: Possible hardware
issue.
Remedy: Clear warnings,
reset the unit, and notify
customer service if the
problem persists.
Related to MII
register read/write
failures.
Clear PHY failure
monitoring reset
Ethernet Port 1 or
Ethernet Port 2
Set ETH Port 1 or 2 Link
Down
Cause: Ethernet port 1 or 2
is not connected.
Remedy: Connect Ethernet
port 1 or 2.
Ethernet port 1 or 2 is
not connected.
Reset ETH Port 1 or 2 Link
Up
FW: Resource Use
PRI
Set Memory or List Near
Full
Cause: Possible software
issue.
Remedy: Clear warnings,
reset the unit, and notify
customer service if the
problem persists.
Software exceeding
allowable usage of
internal constructs.
Clear
Backup Operation
State
Set Backup Active Backup operation
started.
Clear Backup Complete Backup operation
complete.
Backup Failure
Reason
Set Internal Error Cause: Possible software
issue.
Remedy: Check FTP
configuration, reset unit,
and notify customer service
if problem persists.
Software error
occurred.
FTP Failed FTP failed.
Clear Auto reset after
timeout
Warning
automatically clears
in 30 seconds.
Restore Failure
Reason
Set Not Accepted Cause: Possible software
issue.
Remedy: Check FTP
configuration, reset unit,
and notify customer service
if problem persists.
Software error
occurred.
Bad Content
FTP Failed FTP failed.
Clear Auto reset after
timeout
Warning
automatically clears
in 30 seconds.
Warning Message
Type
Message Cause/Remedy Description