TeamPos 3000 XL and XL2

Troubleshooting

8.10Deletion of Date, time and disk setup data when turning off power

No

Check item

Judgment

Action

1

Is the voltage of the lithium battery on

Y

Go to No.2.

the motherboard normal?

N

Change the motherboard.

 

 

Is the “Clear CMOS” jumper on the

Y

Go to No. 3.

2

motherboard set to “normal” (jumper

N

Set jumper correctly.

 

between pins 2-3)

 

 

2

Is operation executed normally after

Y

End.

replacing the motherboard?

N

Change the controller.

 

8.11The system fails to switch to battery backup when power failure occurs

No

Check item

Judgment

Action

1

Is the lead-acid battery connected?

Y

Go to No.2.

N

Connect the battery.

 

 

2

Is the lead-acid battery fuse blown?

Y

Change battery fuse.

N

Go to No.3.

 

 

 

Is the lead-acid battery voltage

Y

Go to No.4.

3

 

 

normal?

N

Recharge or replace the lead

 

 

 

 

battery.

4

Are the cables connected correctly

Y

Go to No.5.

inside the controller?

N

Connect the cable correctly.

 

 

Does the battery backup test function

Y

Check OPOS/JAVAPOS is loaded

5

N

properly.

normally?

 

 

Go to No.6.

 

 

 

 

Can the battery backup be activated

Y

End

6

after replacing the backplane

N

No.7.

 

assembly?

 

 

7

Can the battery backup be activated

Y

End

after replacing the power supply?

N

Go to No.8.

 

8

Can the battery backup be activated

Y

End

after replacing the motherboard?

N

Change the controller.

 

D900000145

Issue 3

8-9

Page 205
Image 205
Fujitsu 3000 XL manual Check item Judgment Action