Polycom 7000 manual Edit External Gatekeeper Dialog, Postliminary

Models: 7000

1 437
Download 437 pages 17.13 Kb
Page 101
Image 101

Device Management

Column

Description

 

 

Enabled

Clearing this check box lets you stop sending H.235 credentials to the

 

external gatekeeper without deleting them.

 

 

Name

The H.235 name of the Polycom RealPresence DMA system.

 

 

Password

The H.235 password for the Polycom RealPresence DMA system.

Confirm password

 

 

 

Algorithm

Select the encryption algorithm for H.235 authentication.

 

 

LRQ test

Click to test the configuration by sending an LRQ message to the external

 

gatekeeper.

 

 

Postliminary

A postliminary is an executable script, written in the Javascript language, that

 

defines dial string transformations to be applied before querying the external

 

gatekeeper.

Enabled

Script

Lets you turn a postliminary on or off without deleting it.

Type (or paste) the postliminary script you want to apply. Then click Debug this script to open the Script Debugging Dialog for Preliminaries/Postliminaries and test the script with various variables.

See also:

External Gatekeeper

Script Debugging Dialog for Preliminaries/Postliminaries

Device Authentication

Edit External Gatekeeper Dialog

The following table describes the fields in the Edit External Gatekeeper dialog.

Column

Description

 

 

External Gatekeeper

Enabled

Name

Description

Address

RAS port

Clearing this check box lets you stop using an external gatekeeper without deleting it.

Gatekeeper name.

The text description displayed in the External Gatekeepers list.

Host name or IP address of the gatekeeper.

The RAS (Registration, Admission and Status) channel port number. Leave set to 1719 unless you know the gatekeeper is using a non-standard port number.

Polycom, Inc.

101

Page 101