System Management and Maintenance

See also:

Alerts

Alert 3205

Cluster <cluster>: DMA VE Soft RPP version is incompatible with license. No calls are permitted.

The specified cluster’s version of software is not compatible with the installed license. The system will not permit calls until a license that has been activated for this version of software is installed.

Click the link to go to the Licenses page to install the proper license activation key. See also:

Alerts

Alert 3206

Cluster <cluster>: DMA is not licensed for any calls.

The current license for the specified cluster does not include the ability to make calls.

Click the link to go to the Licenses page to view licensing details or install a different license activation key. See also:

Alerts

Networks

The following alerts provide information on network errors and connectivity.

Alert 3301

Cluster <cluster> is configured for 2 servers, but only a single server is detected.

One of the servers in the specified cluster is not responding to the other server over the private network that connects them.

This could be a hardware problem, or the server in question may just need to be rebooted. It’s also possible that the private network connection between the two servers has failed. Check the ethernet cable connecting the GB2 ports and replace it if necessary.

See also: Alerts

Alert 3302

Cluster <cluster> is configured for 1 server, but the private network interface is enabled and active.

Either the cluster contains two servers but was incorrectly configured as a single-server cluster, or there is only one server in the cluster but something is connected its GB2 port.

On a single-server cluster, don’t use the server’s GB2 port for anything.