MCU Management
Field | Description |
|
|
Direct | The dialing prefix assigned to the MCU, if any. MCUs without a prefix are |
| unavailable for direct |
| MCUs don’t need a prefix to be used as conferencing resources by the |
| Conference Manager. |
| Gateways don’t need a direct |
| gateway dialing prefixes so that the RealPresence DMA system can choose |
| from a pool of available gateways (see Add Simplified ISDN Gateway Dialing |
| Prefix Dialog). |
|
|
Signaling IP for H.323 | The address that the MCU uses for H.323 signaling. If you specify the login |
| information for the MCU, this field is optional (the system can get the address |
| from the MCU). If not, and H.323 is enabled, this field is required. |
|
|
Signaling IP for SIP | The address that the MCU uses for SIP signaling. If you specify the login |
| information for the MCU, this field is optional (the system can get the address |
| from the MCU). If not, and SIP is enabled, this field is required. |
|
|
Transport type | The SIP transport type to use with this MCU. If the Polycom RealPresence |
| DMA system‘s security settings don’t allow unencrypted connections, this |
| must be TLS. |
|
|
Signaling type | Select SIP, H.323, or both, depending on the configuration of the Polycom |
| RealPresence DMA system and the MCU. |
|
|
Enable for conference rooms | Makes the MCU available as a conferencing resource for the Polycom |
| RealPresence DMA system’s Conference Manager. |
| Up to 64 MCUs can be enabled for conference rooms. |
| Caution: Before adding an MCU to the RealPresence DMA system’s |
| conferencing resources, make sure that MCU isn’t already a RealPresence |
| Resource Manager system conferencing resource. The RealPresence |
| Resource Manager system must have exclusive use of any MCUs on which it |
| directly schedules conferences. |
|
|
Enable gateway profiles | Makes the MCU available for selection as an ISDN gateway device and |
| enables the Gateway Profiles tab for configuring gateway session profiles. |
| Gateway session profiles indicate to the MCU the bandwidth parameters to be |
| used for the ISDN connection. They can be used for: |
| • ISDN gateway calls to the MCU’s direct |
| specifies the session profile prefix in the dial string: |
| <direct |
| prefix><delimiter><E.164 number> |
| • Calls to simplified ISDN gateway dialing prefixes (see Add Simplified ISDN |
| Gateway Dialing Prefix Dialog). In this case, the RealPresence DMA |
| system selects the MCU/gateway and its session profile. See ISDN |
| Gateway Selection Process. |
|
|
Class of service | Select to specify the default class of service and the bit rate limits for this |
| MCU. |
| If specified, calls to the MCU use its class of service or the calling endpoint’s, |
| whichever is better. |
|
|
Maximum bit rate (kbps) | Select the maximum bit rate for calls to this MCU. |
|
|
Polycom, Inc. | 133 |